Pressure sensor with I�C communication ? possibilities and boundary conditions

I�C was designed to communicate over short distances between printed circuit boards and is a simple, 8-bit serial data bus. For the time being, it isn’t only PCB-mountable pressure sensors that use the I�C signal for data transfer, but also pressure sensors remote from customer electronics.
Remote sensors will often have the benefit of being less sensitive to contaminated or aggressive media and having the ability to measure directly at the procedure. In the case of sensors mounted directly on the circuit board, the sensor element is, in many cases, exposed directly to the medium. With remote sensors, steel or ceramic generally serve because the wetted surface.
I�C circuit
The I�C bus, alongside the two supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is really a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than with an analogue signal:
In the data protocol, in addition to the pressure value, a temperature value and diagnostic information (for instance an integrity test of the info transfer) can be transmitted with a status byte.
Several pressure sensors could be linked to a bus line as ?slaves? to the customer electronics that functions as a ?master?.
On Undeniable , in contrast to the application of pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary because the pressure value has already been within digital form. This plays a part in faster and easier signal processing.
The electronics for communication could be built with standard components easily available on the market.
Often, I�C signal pressure sensors are also optimised to take less energy, making them ideal for battery-powered applications. In the WIKA portfolio, for example, this applies to the MPR-1 pressure sensor module.
Demoralizing with the use of I�C
Since I�C isn’t a fieldbus, long wire lengths are not recommended. The maximum wire length depends, in detail, on the operating environment and the corresponding disturbing influences. I�C communication is most beneficial used in projects where the pressure sensor or the pressure sensor module is integrated into the customer product and therefore protected against external influences. It will also be noted that with any digitally processed signal, the response time because of discrete-time sampling will be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will undoubtedly be happy to assist you to with any more questions on digital interfaces.
Distributed Intelligence
Distributed Intelligence on the integration of pressure sensors into hydraulic systems
Fill below form and we’ll send you the whitepaper ?Distributed Intelligence?.
Name
Company
E-mail
Send
We?re committed to your privacy. We?ll use your details to get hold of you about our services. E mail us at socialmedia@wika.com to revoke your permission to use your information.

Leave a Comment